ページの先頭へ

Equipment Handled Item

Elevator openings can be used as effective space

- A tension rod that can be adjusted steplessly to fit the opening
・Installation is as simple as attaching it to a pre-buried scaffolding insert
・By placing scaffolding boards on the main body, it can also be used as a work floor.

Features

  • 開口スライドバー説明図(正面)
    [Front view]
    Attached to pre-buried scaffold inserts
    (Both ends, 2 places on each side)
    Please secure the scaffolding boards
  • 開口スライドバー説明図2
    [Top view]
    The slide bar installation interval should be within 900 mm.
  • 開口スライドバー 両端板
    [Both end plates]
    Scaffolding insert holes (2 locations)
  • 開口スライドバー 固定用ボルト
    [Slide fixing bolt]
    The length can be adjusted to suit the opening span.
  • Scaffolding inserts are embedded into the sides of the frame where there are openings (two on each side).
  • Adjust the length to fit the opening dimensions
  • Use the screws on the scaffolding insert to secure both ends
  • Lay scaffolding boards on the fixed main body (two or more)

Specification

Opening slide bar

Total length mm 1,450~2,500
Pipe mm Φ48.6/Φ42.8 t:2.3
Both end plates mm 65×190×t4.5
Scaffolding insert hole (spacing) mm Φ14 (45-55)
Mass (kg) 9.5
Allowable load kN (kgf) per piece 0.882(90)~2.893(295)※

*The allowable load varies depending on the length, so please check before use.
1,450mm: 2.893(295)
1,451-1,650mm: 2.206(225)
1,651-1,850mm: 1.765(180)
1,851-2,050mm: 1.422(145)
2,051-2,250mm: 1.127(115)
2,251-2,450mm: 0.931(95)
2,451-2,500mm: 0.882(90)